Arcam FMJ CD23 CD player:

Linearity error (fig.4) was very low down to below -100dBFS, with noise then dominating the measurement. This noise can also be seen overlaying the three discrete voltage steps in the waveform of an undithered 1kHz tone at -90.31dBFS (fig.5).

Fig.4 Arcam FMJ CD23, left channel departure from linearity, 16-bit data (2dB/vertical div.).

Fig.5 Arcam FMJ CD23, waveform of undithered 1kHz sinewave at -90.31dBFS, 16-bit data.

The CD23's analog output stage seems to be bombproof. Loading it down with 600 ohms and feeding it with data representing a full-scale 50Hz tone resulted in a negligible amount of third-harmonic distortion and no high-order spuriae (fig.6). Similarly, driving the punishing combination of 19 and 20kHz tones, each at -6dBFS—which results in a waveform peaking at full scale into the same 600 ohm load—revealed negligible intermodulation products (fig.7).

Fig.6 Arcam FMJ CD23, spectrum of 50Hz sinewave, DC-1kHz, at 0dBFS into 600 ohms (linear frequency scale).

Fig.7 Arcam FMJ CD23, HF intermodulation spectrum, DC-22kHz, 19+20kHz at 0dBFS into 600 ohms (linear frequency scale).

Article Continues: Measurements page 3 »
Company Info
Arcam
Web Site

8709 Castle Park Drive
Indianapolis, IN 46256
 
(888) 272-2658

Article TOC
Page 1
Page 2
Page 3
Specifications
Associated Equipment
Measurements
Measurements page 2
Measurements page 3

Sponsored Technology Center

Credit Card Bill me later
Please send me special offers and exclusive promotions from Stereophile's premiere partners.

Stereophile    ::     Home Theater    ::     Ultimate AV    ::     Home Theater Design    ::     Shutterbug    ::     Home Entertainment Show
Home/News • Subscribe • Give a Gift • Sub Services • Digital Subscription
Recordings • Back Issues • Buyer's Guide • Print & Web Media Kit • Privacy • Terms of Use • Contact
RSS News & Reviews • RSS Blogs

Copyright © SOURCE INTERLINK MEDIA All rights reserved.